Durchflussmessung bei Gasenentwicklung

Flow Measurements

The experience of the past has shown that calculations and simulations are not adequate to show the real flows of gasses through valves at very high velocities. In order to prove that valves are able to conduct the flows at the required parameters, flow and losses measurements are a necessity. On our test benches we are able measure air flows up to 300.000 Nm³/h at 400 bar.

Test facilities

Our two test facilities are acc. to EN ISO 5167 and are fully third party inspected by a Third Party.
Frequent applications are:
• Flow measurements for Emergency Blow Valves
• Measurements of flow and pressure losses in pressure reducers and pressure reducing stations
• Measurements of discharge flows for safety valves
• Measurements of Zeta-, Cv- und Kv-values

Specifications

HP-Air bottle volume2400 Liters
Maximum pressure400 bar
Maximum flow300.000 Nm³/h
Nominal diameter of test bench100 mm
Volume Silencer10 m³
Flow of Compressor200 Liter/h bei 400 bar

Do you have any further questions?

Our team is always available to answer your questions quickly and easily.